pycatia.hybrid_shape_interfaces.hybrid_shape_sweep_conic

Module initially auto generated using V5Automation files from CATIA V5 R28 on 2020-07-06 14:02:20.222384

Warning

The notes denoted “CAA V5 Visual Basic Help” are to be used as reference only. They are there as a guide as to how the visual basic / catscript functions work and thus help debugging in pycatia.

class pycatia.hybrid_shape_interfaces.hybrid_shape_sweep_conic.HybridShapeSweepConic(com_object)

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384)

System.IUnknown
System.IDispatch
System.CATBaseUnknown
System.CATBaseDispatch
System.AnyObject
MecModInterfaces.HybridShape
CATGSMIDLItf.HybridShapeSweep
HybridShapeSweepConic

Represents the hybrid shape conic sweep feature.
Role: To access the data of the conic sweep feature .

Use the HybridShapeFactory.AddNewSweepConic to create a HybridShapeConicSweep
object.
property canonical_detection: int

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384)
o Property CanonicalDetection() As long

Returns or sets whether canonical surfaces of the swept surface are
detected.
Legal values:
0 No detection of canonical surface is performed.
2 Detection of canonical surfaces is performed.
Return type:

int

property fifth_guide_crv: Reference

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384)
o Property FifthGuideCrv() As Reference

Returns or sets the fifth guide curve.
Return type:

Reference

property first_guide_crv: Reference

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384)
o Property FirstGuideCrv() As Reference

Returns or sets the first guide curve.
Return type:

Reference

property fourth_guide_crv: Reference

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384)
o Property FourthGuideCrv() As Reference

Returns or sets the fourth guide curve.
Return type:

Reference

get_longitudinal_relimiters(op_ia_elem1: Reference, op_ia_elem2: Reference) None

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384))
o Sub GetLongitudinalRelimiters(Reference opIAElem1,
Reference opIAElem2)

Deprecated:
V5R16 CATHybridShapeSweepConic#GetRelimiters Gets the elements
relimiting the spine (or the default spine).
param : opIAElem1 First relimiting feature (plane or point)
param : opIAElem2 Second relimiting feature (plane or point)
Parameters:
Return type:

None

get_nb_guides(o_num: int) None

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384))
o Sub GetNbGuides(long oNum)

Gets the number of guides.
param : oNum Number of guides curve.
Parameters:

o_num (int) –

Return type:

None

get_parameter_law(o_param_start: float, o_param_end: float, o_law_type: int) None

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384))
o Sub GetParameterLaw(double oParamStart,
double oParamEnd,
long oLawType)

Gets the parameter law used in conic sweep operation.
param : oParamStart Parameter law start value.
param : oParamEnd Parameter law end value.
param : oLawType Parameter law type.
Parameters:
  • o_param_start (float) –

  • o_param_end (float) –

  • o_law_type (int) –

Return type:

None

get_relimiters(op_ia_elem1: Reference, op_orient1: int, op_ia_elem2: Reference, op_orient2: int) None

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384))
o Sub GetRelimiters(Reference opIAElem1,
long opOrient1,
Reference opIAElem2,
long opOrient2)

Retrieves the elements relimiting the spine (or the default
spine).

Parameters:

opIAElem1
The first relimiting feature (plane or point)
opOrient1
Split direction for the first relimitation
0 means that the beginning of the spine (considering its
orientation) is removed, 1 means that the end of the spine is removed

opIAElem2
The second relimiting feature (plane or point)
opOrient2
Split direction for the second relimitation
Parameters:
  • op_ia_elem1 (Reference) –

  • op_orient1 (int) –

  • op_ia_elem2 (Reference) –

  • op_orient2 (int) –

Return type:

None

get_tangency(op_ia_elem: Reference, op_ia_angle_start: Angle, op_ia_angle_end: Angle, o_law_type: int, i_index: int) None

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384))
o Sub GetTangency(Reference opIAElem,
Angle opIAAngleStart,
Angle opIAAngleEnd,
long oLawType,
long iIndex)

Gets tangency surface or curve and its angle given the guide curve
index.
param : opIAElem
param : opIAAngleStart Start tangency angle from surface or curve reference.
param : opIAAngleEnd End tangency angle from surface or curve reference.
param : oLawType Type of law used for tangency angle from surface or curve reference.
param : iIndex Guide curve index : 1 to 5.
Parameters:
  • op_ia_elem (Reference) –

  • op_ia_angle_start (Angle) –

  • op_ia_angle_end (Angle) –

  • o_law_type (int) –

  • i_index (int) –

Return type:

None

get_tangency_angle_law_inversion(i_index: int, o_inversion: int) None

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384))
o Sub GetTangencyAngleLawInversion(long iIndex,
long oInversion)

Gets information whether tangency angle law has to be inverted or not for a
specified guide curve.
param : iIndex Guide curve index : 1 to 5
param : oInversion Non-Zero for TRUE and 0 for FALSE.
Parameters:
  • i_index (int) –

  • o_inversion (int) –

Return type:

None

get_tangency_law(op_ia_elem: Reference, op_ia_law: Reference, i_index: int) None

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384))
o Sub GetTangencyLaw(Reference opIAElem,
Reference opIALaw,
long iIndex)

Gets tangency surface or curve and its angle given the guide curve
index.
param : opIAElem Tangency surface or curve feature.
param : opIALaw Start tangency angle from surface or curve reference.
param : iIndex Guide curve index : 1 to 5.
Parameters:
Return type:

None

property guide_deviation: Length

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384)
o Property GuideDeviation() As Length (Read Only)

Returns deviation value (length) from guide curves allowed during sweeping
operation in order to smooth it.
Return type:

Length

property guide_deviation_activity: bool

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384)
o Property GuideDeviationActivity() As boolean

Returns or sets information whether a deviation from guide curves is
allowed or not.
Gives the information on performing smoothinh during sweeping
operation.
TRUE or FALSE (FALSE if not specified).
Return type:

bool

property parameter: float

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384)
o Property Parameter() As double

Returns or sets the parameter for conic sweep operation.
if the parameter is a law, the method returns FALSE see
HybridShapeLawDistProj
Return type:

float

property parameter_law: Reference

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384)
o Property ParameterLaw() As Reference

Returns or sets the parameter law useful in conic sweep operation.
Return type:

Reference

property parameter_law_inversion: bool

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384)
o Property ParameterLawInversion() As boolean

Returns or sets the parameter law inversion flag of conic sweep
operation.
TRUE if parameter law is inverted. Else it is FALSE. see
HybridShapeLawDistProj
Return type:

bool

property parameter_law_type: int

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384)
o Property ParameterLawType() As long

Returns or sets the parameter law type in conic sweep operation.
Return type:

int

remove_guide(i_index: int) None

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384))
o Sub RemoveGuide(long iIndex)

Removes a guide curve given its index.
it removes also tangency element if specified.
param : iIndex Guide curve index : 1 to 5. If 0, all guides are removed.
Parameters:

i_index (int) –

Return type:

None

remove_parameter() None

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384))
o Sub RemoveParameter()

Removes conical sweep parameter, whether it is a single value or a law.
Return type:

None

remove_tangency(i_index: int) None

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384))
o Sub RemoveTangency(long iIndex)

removes tangency surface or curve and its angle given the guide curve
index.
param : iIndex Guide curve index : 1 to 5.
Parameters:

i_index (int) –

Return type:

None

property second_guide_crv: Reference

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384)
o Property SecondGuideCrv() As Reference

Returns or sets the second guide curve.
Return type:

Reference

set_guide_deviation(i_length: float) None

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384))
o Sub SetGuideDeviation(double iLength)

Sets deviation value (length) from guide curves allowed during sweeping
operation in order to smooth it.
param : iLength Numerical value.
Parameters:

i_length (float) –

Return type:

None

set_longitudinal_relimiters(ip_ia_elem1: Reference, ip_ia_elem2: Reference) None

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384))
o Sub SetLongitudinalRelimiters(Reference ipIAElem1,
Reference ipIAElem2)

Deprecated:
V5R16 CATHybridShapeSweepConic#SetRelimiters Sets the elements
relimiting the spine (or the default spine).
param : ipIAElem1 First relimiting feature (plane or point)
param : ipIAElem2 Second relimiting feature (plane or point)
Parameters:
Return type:

None

set_parameter_law(i_param_start: float, i_param_end: float, i_law_type: int) None

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384))
o Sub SetParameterLaw(double iParamStart,
double iParamEnd,
long iLawType)

Sets the parameter law that will be used in conic sweep
operation.
param : iParamStart Parameter law start value.
param : iParamEnd Parameter law end value.
param : iLawType Parameter law type.
Parameters:
  • i_param_start (float) –

  • i_param_end (float) –

  • i_law_type (int) –

Return type:

None

set_relimiters(ip_ia_elem1: Reference, ip_orient1: int, ip_ia_elem2: Reference, ip_orient2: int) None

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384))
o Sub SetRelimiters(Reference ipIAElem1,
long ipOrient1,
Reference ipIAElem2,
long ipOrient2)

Sets the elements relimiting the spine (or the default
spine).

Parameters:

ipIAElem1
The first relimiting feature (plane or point)
ipOrient1
Split direction for the first relimitation
0 means that the beginning of the spine (considering its
orientation) is removed, 1 means that the end of the spine is removed

ipIAElem2
The second relimiting feature (plane or point)
ipOrient2
Split direction for the second relimitation
Parameters:
  • ip_ia_elem1 (Reference) –

  • ip_orient1 (int) –

  • ip_ia_elem2 (Reference) –

  • ip_orient2 (int) –

Return type:

None

set_smooth_angle_threshold(i_angle: float) None

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384))
o Sub SetSmoothAngleThreshold(double iAngle)

Sets angular threshold under which discontinuities.
note: moving frame,tangency net on reference surface will be smoothed when
sweeping.
param : iAngle Numerical value.
Parameters:

i_angle (float) –

Return type:

None

set_tangency(ip_ia_elem: Reference, i_angle_start: float, i_angle_end: float, ilaw_type: int, i_index: int) None

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384))
o Sub SetTangency(Reference ipIAElem,
double iAngleStart,
double iAngleEnd,
long ilawType,
long iIndex)

Sets tangency surface or curve and its angle given the guide curve
index.
param : ipIAElem Tangency surface or curve feature.
param : iAngleStart Start tangency angle from surface or curve reference.
param : iAngleEnd End tangency angle from surface or curve reference.
param : iAngleLawType Type of law used for tangency angle from surface or curve reference.
param : iIndex Guide curve index : 1 to 5.
Parameters:
  • ip_ia_elem (Reference) –

  • i_angle_start (float) –

  • i_angle_end (float) –

  • ilaw_type (int) –

  • i_index (int) –

Return type:

None

set_tangency_angle_law_inversion(i_index: int, i_inversion: int) None

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384))
o Sub SetTangencyAngleLawInversion(long iIndex,
long iInversion)

Sets information whether tangency angle law has to be inverted or not for a
specified guide curve.
param : iIndex Guide curve index : 1 to 5
param : iInversion 1 for TRUE and 0 for FALSE.
Parameters:
  • i_index (int) –

  • i_inversion (int) –

Return type:

None

set_tangency_law(ip_ia_elem: Reference, ip_ia_law: Reference, i_index: int) None

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384))
o Sub SetTangencyLaw(Reference ipIAElem,
Reference ipIALaw,
long iIndex)

Sets tangency surface or curve and its angle given the guide curve
index.
param : ipIAElem Tangency surface or curve feature.
param : ipIALaw Start tangency angle from surface or curve reference.
param : iIndex Guide curve index : 1 to 5.
Parameters:
Return type:

None

property smooth_activity: bool

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384)
o Property SmoothActivity() As boolean

Returns or sets information whether sweeping operation is smoothed or
not.
TRUE or FALSE (FALSE if not specified).
Return type:

bool

property smooth_angle_threshold: Angle

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384)
o Property SmoothAngleThreshold() As Angle (Read Only)

Returns angular threshold under which discontinuities .
moving frame,tangency net on reference surface will be smoothed when
sweeping.
Return type:

Angle

property spine: Reference

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384)
o Property Spine() As Reference

Returns or sets the spine (optional) for sweep operation.
param : oElem Spine curve.

See also:
Reference
Return type:

Reference

property third_guide_crv: Reference

Note

CAA V5 Visual Basic Help (2020-07-06 14:02:20.222384)
o Property ThirdGuideCrv() As Reference

Returns or sets the third guide curve.
Return type: