pycatia.dnb_human_modeling_interfaces.swk_ergo_lift_lower

Module initially auto generated using V5Automation files from CATIA V5 R28 on 2020-09-25 14:34:21.593357

Warning

The notes denoted “CAA V5 Visual Basic Help” are to be used as reference only. They are there as a guide as to how the visual basic / catscript functions work and thus help debugging in pycatia.

class pycatia.dnb_human_modeling_interfaces.swk_ergo_lift_lower.SWKErgoLiftLower(com_object)

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)

System.IUnknown
System.IDispatch
System.CATBaseUnknown
System.CATBaseDispatch
System.AnyObject
SWKErgoLiftLower

This interface deals the lift/lower ergonomic analysis.
property coupling: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property Coupling() As CATBSTR

Returns or sets the coupling condition for the lift/lower
analysis.
The value of the parameter must be either “Good”, “Fair”, or
“Poor”.

N.B.: This coupling condition must be set before
attempting
to retrive any output value from the study, if the input gudeline
is “NIOSH1991”. Failure to do so will result in invalid output
values.
Return type:

str

property duration: float

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property Duration() As double

Returns or sets the lift duration.
This frequency must be expressed in hours per day, cannot be greater
than 8.0 and must be specified before attempting to retrive any output
value from the study.
Failure to do so will result in invalid output values.
Return type:

float

property frequency: float

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property Frequency() As double

Returns or sets the lift frequecy.
This frequency must be expressed in lifts per second, and must
be specified before attempting to retrive any output value from the
study.
Failure to do so will result in invalid output values.
Return type:

float

property guide_line: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property GuideLine() As CATBSTR

Returns or sets the guideline for the lift/lower analysis.
The value of the parameter must be either “NIOSH1981”, “NIOSH1991”, or
“SnookCiriello1991”.

N.B.: This guideline must be set before attempting
to retrive any output value from the study, otherwise these outputs
will have invalid values.
Return type:

str

property niosh_action_limit: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property NIOSH_ActionLimit() As CATBSTR (Read Only)

This field is set to a valid value for the NIOSH 1981 analysis only.
It is the weight below which the task could be considered reasonably
safe.
Return type:

str

property niosh_angle_of_asymmetry_final: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property NIOSH_AngleOfAsymmetryFinal() As CATBSTR (Read
Only)

This field is set to a valid value for the NIOSH 1991 analysis
only.
This value provides the angular measure of how far the object is displaced
from the front (mid-sagital plane) of the worker’s body at the ending of the
lift, in in the current V5 units.
This property gives the asymmetry angle at the destination
(i.e., given the final posture of the manikin).
Return type:

str

property niosh_angle_of_asymmetry_initial: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property NIOSH_AngleOfAsymmetryInitial() As CATBSTR (Read
Only)

This field is set to a valid value for the NIOSH 1991 analysis
only.
This value provides the angular measure of how far the object is displaced
from the front (mid-sagital plane) of the worker’s body at the beginning of the
lift, in in the current V5 units.
This property gives the asymmetry angle at the origin
(i.e., given the initial posture of the manikin).
Return type:

str

property niosh_asymmetric_multiplier_final: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property NIOSH_AsymmetricMultiplierFinal() As CATBSTR (Read
Only)

This field is set to a valid value for the NIOSH 1991 analysis
only.
This value provides the asymmetric multiplier.
This property gives the asymmetric multiplier at the
destination
(i.e., given the final posture of the manikin).
Return type:

str

property niosh_asymmetric_multiplier_initial: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property NIOSH_AsymmetricMultiplierInitial() As CATBSTR (Read
Only)

This field is set to a valid value for the NIOSH 1991 analysis
only.
This value provides the asymmetric multiplier.
This property gives the asymmetric multiplier at the
origin
(i.e., given the initial posture of the manikin).
Return type:

str

property niosh_coupling_multiplier_final: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property NIOSH_CouplingMultiplierFinal() As CATBSTR (Read
Only)

This field is set to a valid value for the NIOSH 1991 analysis
only.
This value provides the coupling multiplier bases ont hte coupling
classification and vertical location of the lift (V).
This property gives the coupling multiplier at the
destination
(i.e., given the final
Return type:

str

property niosh_coupling_multiplier_initial: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property NIOSH_CouplingMultiplierInitial() As CATBSTR (Read
Only)

This field is set to a valid value for the NIOSH 1991 analysis
only.
This value provides the coupling multiplier bases ont hte coupling
classification and vertical location of the lift (V).
This property gives the coupling multiplier at the origin
(i.e., given the initial posture of the manikin).
Return type:

str

property niosh_distance_multiplier: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property NIOSH_DistanceMultiplier() As CATBSTR (Read Only)

This field is set to a valid value for the NIOSH 1991 analysis
only.
This value provides the distance multiplier.
This property gives the distance multiplier.
Return type:

str

property niosh_frequency_multiplier: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property NIOSH_FrequencyMultiplier() As CATBSTR (Read Only)

This field is set to a valid value for the NIOSH 1991 analysis
only.
This value provides the frequency depending upon the average of lifts/min
(F), the vertical location (V) of the hand at the origin, and the duration of
continuous lifting.
This property gives the frequency multiplier.
Return type:

str

property niosh_horizontal_location_final: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property NIOSH_HorizontalLocationFinal() As CATBSTR (Read
Only)

This field is set to a valid value for the NIOSH 1991 analysis
only.
This value provides the distance of the hands from the mid-point between
the ankles, in in the current V5 units.
This property gives the horizontal location at the
destination
(i.e., given the final posture of the manikin).
Return type:

str

property niosh_horizontal_location_initial: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property NIOSH_HorizontalLocationInitial() As CATBSTR (Read
Only)

This field is set to a valid value for the NIOSH 1991 analysis
only.
This value provides the distance of the hands from the mid-point between
the ankles, in in the current V5 units.
This property gives the horizontal location at the origin
(i.e., given the initial posture of the manikin).
Return type:

str

property niosh_horizontal_multiplier_final: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property NIOSH_HorizontalMultiplierFinal() As CATBSTR (Read
Only)

This field is set to a valid value for the NIOSH 1991 analysis
only.
This value provides the horizontal multiplier.
This property gives the horizontal multiplier at the
destination
(i.e., given the final posture of the manikin).
Return type:

str

property niosh_horizontal_multiplier_initial: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property NIOSH_HorizontalMultiplierInitial() As CATBSTR (Read
Only)

This field is set to a valid value for the NIOSH 1991 analysis
only.
This value provides the horizontal multiplier.
This property gives the horizontal multiplier at the
origin
(i.e., given the initial posture of the manikin).
Return type:

str

property niosh_li_final: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property NIOSH_LIFinal() As CATBSTR (Read Only)

This field is set to a valid value for the NIOSH 1991 analysis
only.
This value provides a relative estimate of the level of physical
stress.
This property gives the lifting index at the destination
(i.e., given the final posture of the manikin).
Return type:

str

property niosh_li_initial: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property NIOSH_LIInitial() As CATBSTR (Read Only)

This field is set to a valid value for the NIOSH 1991 analysis
only.
This value provides a relative estimate of the level of physical
stress.
This property gives the lifting index at the origin
(i.e., given the initial posture of the manikin).
Return type:

str

property niosh_load_constant: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property NIOSH_LoadConstant() As CATBSTR (Read Only)

This field is set to a valid value for the NIOSH 1991 analysis
only.
This value provides the load constant.
This property gives the load constant at the destination
(i.e., given the final posture of the manikin).
Return type:

str

property niosh_maximum_perm_limit: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property NIOSH_MaximumPermLimit() As CATBSTR (Read Only)

This field is set to a valid value for the NIOSH 1981 analysis
only.
This value represents a weight limit, above which the
task is considered dangerous and requires engineering controls.
Return type:

str

property niosh_rwl_final: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property NIOSH_RWLFinal() As CATBSTR (Read Only)

This field is set to a valid value for the NIOSH 1991 analysis
only.
It represents the weight of the load, that healthy workers
could
perform over a certain period of time without risk.
This property gives the recommended weight at the
destination
(i.e., given the final posture of the manikin).
Return type:

str

property niosh_rwl_initial: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property NIOSH_RWLInitial() As CATBSTR (Read Only)

This field is set to a valid value for the NIOSH 1991 analysis
only.
It represents the weight of the load that healthy workers
could perform over a certain period of time without risk.
This property gives the recommended weight at the origin
(i.e., given the initial posture of the manikin).
Return type:

str

property niosh_travel_distance: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property NIOSH_TravelDistance() As CATBSTR (Read Only)

This field is set to a valid value for the NIOSH 1991 analysis
only.
This value provides the absolute value of the difference between the
vertical heights at the destination and origin of the lift, in in the current
V5 units.
This property gives the travel distance
Return type:

str

property niosh_vertical_location_final: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property NIOSH_VerticalLocationFinal() As CATBSTR (Read
Only)

This field is set to a valid value for the NIOSH 1991 analysis
only.
This value provides the distance of the hands above the floor, in the
current V5 units.
This property gives the vertical location at the
destination
(i.e., given the final posture of the manikin).
Return type:

str

property niosh_vertical_location_initial: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property NIOSH_VerticalLocationInitial() As CATBSTR (Read
Only)

This field is set to a valid value for the NIOSH 1991 analysis
only.
This value provides the distance of the hands above the floor, in in the
current V5 units.
This property gives the vertical location at the origin
(i.e., given the initial posture of the manikin).
Return type:

str

property niosh_vertical_multiplier_final: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property NIOSH_VerticalMultiplierFinal() As CATBSTR (Read
Only)

This field is set to a valid value for the NIOSH 1991 analysis
only.
This value provides the absolute value or deviation of V (vertical
location) from an optimum height of 30 inches (75 cm).
This property gives the vertical multiplier at the
destination
(i.e., given the final posture of the manikin).
Return type:

str

property niosh_vertical_multiplier_initial: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property NIOSH_VerticalMultiplierInitial() As CATBSTR (Read
Only)

This field is set to a valid value for the NIOSH 1991 analysis
only.
This value provides the absolute value or deviation of V (vertical
location) from an optimum height of 30 inches (75 cm).
This property gives the vertical multiplier at the origin
(i.e., given the initial posture of the manikin).
Return type:

str

property object_weight: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property ObjectWeight() As CATBSTR

Returns or sets the weight of the object being lifted.
This weight must specified at least once, if the current input guideline is
“NIOSH1991”.
Failure to do so will result in invalid output values.
Return type:

str

property population: float

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property Population() As double

Returns or sets the percentage of the population that should be able to
perform the lift/lower task safely.
This property can only take the values 50.0, 75.0 and 90.0,and must be
specified
at least once, if the current input guideline is
“NIOSH1991”.
Failure to do so will result in invalid output values.
Return type:

float

save_final_posture() None

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357))
o Sub SaveFinalPosture()

Saves the current posture of the mankin as the final posture for the
lift/lower analysis.
Return type:

None

save_initial_posture() None

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357))
o Sub SaveInitialPosture()

Saves the current posture of the mankin as the initial posture for the
lift/lower analysis.
Return type:

None

property snook_maximum_weight: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property Snook_MaximumWeight() As CATBSTR (Read Only)

This field is set to a valid value for the Snook/Ciriello 1991 analysis
only.
It is the maximum acceptable weight of the load that the selected
population
can lift or carry with reasonable safety.
Return type:

str

property warning_message: str

Note

CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
o Property WarningMessage() As CATBSTR (Read Only)

Returns an eventual warning message generated along with the study.
Return type:

str