pycatia.abq_automation_interfaces.abqiaabq_steady_state_lin_dyn_step_modal_vb¶
Module initially auto generated using V5Automation files from CATIA V5 R28 on 2020-09-25 14:34:21.593357
Warning
The notes denoted “CAA V5 Visual Basic Help” are to be used as reference only. They are there as a guide as to how the visual basic / catscript functions work and thus help debugging in pycatia.
- class pycatia.abq_automation_interfaces.abqiaabq_steady_state_lin_dyn_step_modal_vb.ABQIAABQSteadyStateLinDynStepModalVB(com_object)¶
Note
CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
System.IUnknownSystem.IDispatchSystem.CATBaseUnknownSystem.CATBaseDispatchSystem.AnyObjectABQAutomationItf.ABQStepABQAutomationItf.ABQIAABQSteadyStateLinDynStepBasicVBABQIAABQSteadyStateLinDynStepModalVBInterface representing xxx.Role: Components that implement ABQIAABQSteadyStateLinDynStepModal are…Do not use the ABQIAABQSteadyStateLinDynStepModal interface for such and suchClassReference, Class#MethodReference, #InternalMethod…- add_composite_damping_data_table(i_column1: tuple, i_column2: tuple) None ¶
Note
- CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357))
- o Sub AddCompositeDampingDataTable(CATSafeArrayVariantiColumn1,CATSafeArrayVariant iColumn2)Adds a composite damping data over ranges of Modes or Frequencies Thenumber of values in both the parameters must match. If either list containsextra values, the extra values are discarded. Valid only for damping overranges of Modes.Parameters:iColumn1The list of start modes.iColumn2The list of end modes.
- Parameters:
i_column1 (tuple) –
i_column2 (tuple) –
- Return type:
None
- add_direct_damping_data_table(i_damping_range: str, i_column1: tuple, i_column2: tuple, i_column3: tuple) None ¶
Note
- CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357))
- o Sub AddDirectDampingDataTable(CATBSTR iDampingRange,CATSafeArrayVariant iColumn1,CATSafeArrayVariant iColumn2,CATSafeArrayVariant iColumn3)Adds a direct damping data over ranges of Modes or Frequencies The numberof values in all the three of the parameters must match. If either listcontains extra values, the extra values are discarded.Parameters:iDampingRangeThe range over which damping is defined.Legal values:MODES.FREQUENCIES.iColumn1For daming range = MODES - The list of start modes.For daming range = FREQUENCIES - The list of frequencies.iColumn2For daming range = MODES - The list of end modes.For daming range = FREQUENCIES - The list of critical damping fraction.iColumn3For daming range = MODES - The list of critical damping fraction.For daming range = FREQUENCIES - iColumn3 will be ignored if the damping range is FREQUENCIES.
- Parameters:
i_damping_range (str) –
i_column1 (tuple) –
i_column2 (tuple) –
i_column3 (tuple) –
- Return type:
None
- add_rayleigh_damping_data_table(i_damping_range: str, i_column1: tuple, i_column2: tuple, i_column3: tuple, i_column4: tuple) None ¶
Note
- CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357))
- o Sub AddRayleighDampingDataTable(CATBSTR iDampingRange,CATSafeArrayVariant iColumn1,CATSafeArrayVariant iColumn2,CATSafeArrayVariant iColumn3,CATSafeArrayVariant iColumn4)Adds a rayleigh damping data over ranges of Modes or Frequencies The numberof values in all the four of the parameters must match. If either list containsextra values, the extra values are discarded.Parameters:iDampingRangeThe range over which damping is defined.Legal values:MODES.FREQUENCIES.iColumn1For daming range = MODES - The list of start modes.For daming range = FREQUENCIES - The list of frequencies.iColumn2For daming range = MODES - The list of end modes.For daming range = FREQUENCIES - The list of alpha coefficients.iColumn3For daming range = MODES - The list of alpha coefficients.For daming range = FREQUENCIES - The list of beta coefficients.iColumn4For daming range = MODES - The list of beta coefficients.For daming range = FREQUENCIES - iColumn4 will be ignored if the damping range is FREQUENCIES.
- Parameters:
i_damping_range (str) –
i_column1 (tuple) –
i_column2 (tuple) –
i_column3 (tuple) –
i_column4 (tuple) –
- Return type:
None
- add_structural_damping_data_table(i_damping_range: str, i_column1: tuple, i_column2: tuple, i_column3: tuple) None ¶
Note
- CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357))
- o Sub AddStructuralDampingDataTable(CATBSTR iDampingRange,CATSafeArrayVariant iColumn1,CATSafeArrayVariant iColumn2,CATSafeArrayVariant iColumn3)Adds a structural damping data over ranges of Modes or Frequencies Thenumber of values in all the three of the parameters must match. If either listcontains extra values, the extra values are discarded.Parameters:iDampingRangeThe range over which damping is defined.Legal values:MODES.FREQUENCIES.iColumn1For daming range = MODES - The list of start modes.For daming range = FREQUENCIES - The list of frequencies.iColumn2For daming range = MODES - The list of end modes.For daming range = FREQUENCIES - The list of damping constant.iColumn3For daming range = MODES - The list of damping constant.For daming range = FREQUENCIES - iColumn3 will be ignored if the damping range is FREQUENCIES.
- Parameters:
i_damping_range (str) –
i_column1 (tuple) –
i_column2 (tuple) –
i_column3 (tuple) –
- Return type:
None
- property use_composite_damping_data: bool¶
Note
- CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
- o Property UseCompositeDampingData() As booleanSets or returns if the composite damping data is ued.Returns:A boolean specifying whether the composite damping data is ued.
- Return type:
bool
- property use_direct_damping_data: bool¶
Note
- CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
- o Property UseDirectDampingData() As booleanSets or returns if the direct damping data is ued.Returns:A boolean specifying whether the direct damping data is ued.
- Return type:
bool
- property use_rayleigh_damping_data: bool¶
Note
- CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
- o Property UseRayleighDampingData() As booleanSets or returns if the rayleigh damping data is ued.Returns:A boolean specifying whether the rayleigh damping data is ued.
- Return type:
bool
- property use_structural_damping_data: bool¶
Note
- CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
- o Property UseStructuralDampingData() As booleanSets or returns if the structural damping data is ued.Returns:A boolean specifying whether the structural damping data is ued.
- Return type:
bool