pycatia.abq_automation_interfaces.abq_frequency_step¶
Module initially auto generated using V5Automation files from CATIA V5 R28 on 2020-09-25 14:34:21.593357
Warning
The notes denoted “CAA V5 Visual Basic Help” are to be used as reference only. They are there as a guide as to how the visual basic / catscript functions work and thus help debugging in pycatia.
- class pycatia.abq_automation_interfaces.abq_frequency_step.ABQFrequencyStep(com_object)¶
Note
CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
System.IUnknownSystem.IDispatchSystem.CATBaseUnknownSystem.CATBaseDispatchSystem.AnyObjectABQAutomationItf.ABQStepABQFrequencyStepRepresents an Abaqus frequency step (ABQFrequencyStep) object.Role: Access an Abaqus frequency step object or determine itsproperties.- add_residual_mode_region(i_product: Product, i_support: Reference) None ¶
Note
- CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357))
- o Sub AddResidualModeRegion(Product iProduct,Reference iSupport)Adds the Residual Mode Region.Parameters:iProductThe CATIAProduct specifying the positioningobject.iSupportThe CATIAReference specifying the object that is being pointedto.
- add_residual_mode_region_dof(i_dof: int, i_index: int) None ¶
Note
- CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357))
- o Sub AddResidualModeRegionDOF(short iDOF,short iIndex)Adds the Residual Mode Region DOF.Parameters:iDOFThe DOF.iIndexThe index at which the DOF is being set.
- Parameters:
i_dof (int) –
i_index (int) –
- Return type:
None
- property boundary_conditions: ABQBoundaryConditions¶
Note
- CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
- o Property BoundaryConditions() As ABQBoundaryConditions (ReadOnly)Returns the ABQBoundaryConditions container associated with thestep.Example:This example retrieves the ABQBoundaryConditions containerabqBCs.Dim abqFreqStep As ABQFrequencyStepDim abqBCs As ABQBoundaryConditionsSet abqBCs = abqFreqStep.BoundaryConditions
- Return type:
- property description: str¶
Note
- CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
- o Property Description() As CATBSTRReturns or sets the description of the Abaqus general staticstep.Returns:The description of the Abaqus general static step.
- Return type:
str
- property eigensolver_value: int¶
Note
- CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
- o Property EigensolverValue() As shortReturns or sets Eigensolver Value.Returns:The Eigensolver Value.Legal values:1 - Lanczos.2 - AMS.Example:This example sets eigensolver as LanczosabqFreqStepabqFreqStep.EigensolverValue = 1
- Return type:
int
- property frequency_shift: int¶
Note
- CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
- o Property FrequencyShift() As shortReturns or sets frequency shift value.Returns:The frequency shift value.Example:This example sets the maximum frequency forabqFreqStepabqFreqStep.FrequencyShift = 10
- Return type:
int
- property loads: ABQLoads¶
Note
- CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
- o Property Loads() As ABQLoads (Read Only)Returns the ABQLoads container associated with the step.Example:The following example retrieves the ABQLoads containerabqLoads:Dim abqFreqStep As ABQFrequencyStepDim abqLoads As ABQLoadsSet abqLoads = abqFreqStep.Loads
- Return type:
- property maximum_frequency: int¶
Note
- CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
- o Property MaximumFrequency() As shortReturns or sets maximum frequency value.Returns:The maximum frequency value.Example:This example sets the maximum frequency forabqFreqStepabqFreqStep.MaximumFrequency = 100
- Return type:
int
- property minimum_frequency: int¶
Note
- CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
- o Property MinimumFrequency() As shortReturns or sets minimum frequency value.Returns:The minimum frequency value.Example:This example sets the minimum frequency forabqFreqStepabqFreqStep.MinimumFrequency = 10
- Return type:
int
- property normalization_value: int¶
Note
- CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
- o Property NormalizationValue() As shortReturns or sets Normalization Value.Returns:The Normalization Value.Legal values:1 - Displacement.2 - Mass.Example:This example sets Normalization as DisplacementabqFreqStepabqFreqStep.NormalizationValue = 1
- Return type:
int
- property requested_modes_option: int¶
Note
- CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
- o Property RequestedModesOption() As shortSets or returns the requested modes option.Returns:The option of requested modes.Legal values:ABQ_ALL - All modes.ABQ_VALUE - Specify the no of modes to be requested.Example:This example sets the requested modes option for abqFreqStep job toevery increment.abqFreqStep.RequestedModesOption = ABQ_ALL
- Returns:
enum abq_requested_modes_option
- Return type:
int
- property requested_modes_value: int¶
Note
- CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
- o Property RequestedModesValue() As shortReturns or sets requested modes value. This is only valid ifRestartRequestOption is ABQ_VALUEReturns:The requested modes value.Example:This example sets the requested modes forabqFreqStepabqFreqStep.RequestedModesValue = 10
- Return type:
int
- property residual_mode_req_boolean: bool¶
Note
- CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
- o Property ResidualModeReqBoolean() As booleanReturns or sets Residual Mode Request Boolean Value.Returns:The Residual Mode Request Boolean Value.
- Return type:
bool
- property sim_architecture_req_boolean: bool¶
Note
- CAA V5 Visual Basic Help (2020-09-25 14:34:21.593357)
- o Property SIMArchitectureReqBoolean() As booleanReturns or sets SIM Architecture Request Boolean Value.Returns:The SIM Architecture Request Boolean Value.
- Return type:
bool